Kia Soul: Cooling Fan Description
Kia Soul 2014-2019 PS Service Manual / Engine Mechanical System / Cooling System / Cooling Fan Description
[Air conditioning type]
The cooling fan operates in 2 stages (HIGH/LOW). The engine control module
(ECM) controls the cooling fan according to the coolant temperature, vehicle
speed and A/C operation.
[Cooling fan operation conditions]
A/C switch |
A/C pressure
[kgf/cm² G (psi G)] |
Vehicle speed
[km/h (mph)] |
Coolant temperature
[°C (°F)] |
Cooling fan speed |
OFF |
ㅡ |
V < 45 (28) |
95 ~ 100 (203 ~ 212) |
LOW |
100 (212) or above |
HIGH |
|||
45 (28) ≤ V < 80 (49.7) |
95 ~ 100 (203 ~ 212) |
LOW |
||
100 (212) or above |
HIGH |
|||
80 (49.7) ≤ V |
105 (221) or above |
HIGH |
||
ON |
P < 6 (85.3) |
All |
105 (221) or above |
HIGH |
6 (85.3) ≤ P < 12 (170.7) |
V < 45 (28) |
45 ~ 100 (113 ~ 212) |
LOW |
|
100 (212) or above |
HIGH |
|||
45 (28) ≤ V < 80 (49.7) |
95 ~ 100 (203 ~ 212) |
LOW |
||
100 (212) or above |
HIGH |
|||
80 (49.7) ≤ V |
105 (221) or above |
HIGH |
||
12 (170.7) ≤ P < 15.5 (120.5) |
V < 45 (28) |
-30 ~ 95 (-22 ~ 203) |
LOW |
|
95 (203) or above |
HIGH |
|||
45 (28) ≤ V < 80 (49.7) |
95 ~ 100 (203 ~ 212) |
LOW |
||
100 (212) or above |
HIGH |
|||
80 (49.7) ≤ V |
105 (221) or above |
HIGH |
||
15.5 (120.5) ≤ P |
All |
-30 (-22) or above |
HIGH |
[Non-Air conditioning type]
The cooling fan operates in 1 stages (HIGH). The engine control module
(ECM) controls the cooling fan according to the coolant temperature, vehicle
speed and A/C operation.
[Cooling fan operation conditions]
A/C switch |
A/C pressure [kgf/cm² G (psi G)] |
Vehicle speed [km/h (mph)] |
Coolant temperature [°C (°F)] |
Cooling fan speed |
OFF |
ㅡ |
V < 45 (28) |
95 ~ 100 (203 ~ 212) or above |
HIGH |
45 (28) ≤ V < 80 (49.7) |
95 ~ 100 (203 ~ 212) or above |
HIGH |
||
80 (49.7) ≤ V |
105 (221) or above |
HIGH |
Cooling Fan Components
1. Cooling fan mounting retainer 2. Torque washer 3. Cooling fan 4. Fan motor 5. Cooling fan shroud 6. Cooling fan resistor ...Cooling Fan Specifications
Item Specification Motor capacity (W) 140 (With A/C) 120 (Without A/C) Fan type Puller Puller Fan speed control ...See also:
Instrument Cluster Components
Connector Pin Information
No.
Description
No.
Description
1
Ground signal 3
21
Trip switch (-) input
...
Canister Inspection
1.
Check for the following items visually.
- Cracks or leakage of the canister
- Loose connection, distortion, or damage of the vapor hose/tube
A ...
Clean air(if equipped)
When the ignition switch is in the ON position, the clean air function turns on automatically.
Also, the clean air function turns off automatically, when the ignition switch turns to the OFF posi ...